CASB393 - Fire Alarm System Visual Alarm Device

CASB393 - Fire Alarm System Visual Alarm Device Intelligent Addressable Open Class VAD

The new intelligent addressable open class visual alarm device (CASB393) combines the high output sound of the wall sounders with a brighter LED.

It is compliant to EN54-23, 3 and 17 making it suitable for use as a Fire notification device within Europe.  
 
Part no: CASB393 / CASB393WP
 
Other variants:
FXN559LPS / FXN559LPSWP - Menvier                             MASB880 / MASB880WP - JSB 
 
Please be aware that the below specification sheets and manuals refer to Eaton's variant but are applicable to all Menveir/JSB.
 

Download Technical Documentation

The new intelligent addressable open class visual alarm device (CASB393) combines the high output sound of the wall sounders with a brighter LED. It is compliant to EN54-23, 3 and 17 making it suitable for use as a Fire notification device within Europe.  
 
The CASB393 offers low current consumption, maximising the number of devices that can be fitted on a loop and provides a flexible solution due to it soft addressing, multiple tone and body options.   
 
The open class VAD comes in two variants, the standard CASB393 and the weatherproof CASB393WP, which is IP66 rated meaning it is ideal for outdoor locations.
 
With both variants, the open class VAD is suitable for all markets where EN54-23 VADs are now a requirement.
 

Features and benefits

  • Integral short circuit isolator
  • Loop powered
  • Soft addressed
  • Quick and simple to install
  • Selectable tones controlled by the panel
  • Adjustable volume controlled by the panel
  • IP66 version available as both an internal and weatherproof variant available
  • Easy to maintain/service

Code

CASB393/CASB393WP/ FXN559LPS / FXN559LPSWP/MASB880 / MASB880WP

Supply Voltage

19 – 30vdc

Cable Size / type

0.5 - 2.5mm/ FIRETUF, FP200 or MICC

Standby current

< 450 uA

Operating temperature

-10 to +55 degrees C (95%RH)

Sound output @ +/-3d8 (set by panel)

Low volume : 87dB @ <8.6mA

Medium volume : 93dB @ <10mA

High volume : 100dB @ <11mA

Environment Category CASB393

Type A

Environment Category CASB393WP

Type B

Compliance

EN54-3 Fire Alarm Device – Sounder

EN54-17:2005

EN54-23:2010 Fire Alarm Device - VAD

Tones (set by panel)

Continuous 984Hz

Pulsed 984 / 0Hz pulse 1Hz*

Two Tone 644 / 984Hz @ 1Hz cycle

Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

Beacon

0.5Hz Flash

Total Loop Resistance for correct operation of short circuit isolator

50Ω (max)

Parallel Fault Resistance to be seen at the Control Panel for isolators to open

200Ω (typ)

Continuous Current allowable through isolator

700mA (max)

Isolator Resistance in closed state

0.26Ω (max)

Leakage Current into direct short circuit with isolator open

14mA (max)

Voltage at which isolator changes from open to closed or closed to open state

3.8V to 11V

Maximum switching current of isolator

1.5A

 

Eaton (Cooper) variant:
 
CASB393
VAD wall sounder beacon
CASB393WP
Weatherproof wall sounder beacon

Menvier variant:

FXN559LPS
VAD wall sounder beacon
FXN559LPSWP
Weatherproof wall sounder beacon

JSB variant:

MASB880
VAD wall sounder beacon
MASB880WP
Weatherproof wall sounder beacon

 

 

Need more help?

For further help and support please contact our Technical Support team:

Technical Support
techsupport@cooperfire.com
Tel: 01302 303350
Fax: 01302 303332