Sorry, you need to enable JavaScript to visit this website.

CF1000VDS Fire Alarm Control Panel Range

CF1000VDS Fire Alarm Control Panel Range Intelligent Addressable Control Panel

The CF1000VDS range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation. This addressable control panel offers a perfect fire alarm system for a small or medium fire safety projects. 

The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects.

Download Technical Documentation

The CF1000VDS range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation.

The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide
range of small to medium sized projects. CF1000VDS uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing.

These panels can operate as a stand alone panel or as part of a network with the Cooper range of CF3000 panels or other CF1000VDS panels (additional network card required).

The CF1000VDS range of panels have an integral power supply and are supplied with batteries as standard.

An extensive range of compatible intelligent addressable system ancillaries are available to work with the CF1000VDS range all of which incorporate an integral short circuit isolator to provide maximum protection against short circuit faults on the loop.

Features

  • Available in 1 and 2 loop versions
  • Up to 200 addresses per loop
  • Full network capability up to 126 panels
  • Soft addressing
  • Large versatile touch-screen user interface
  • Multi-language selection capability
  • Integral battery and power supply
  • Flexible cause and effect programming

Benefits

  • Simple to operate end user touch-screen interface
  • Flexible distributed network capability
  • Full range of compatible accessories
  • Easy to design system cause and effect using site installer software
  • Full system integrity with Cooper developed protocol

Compliant for the German market - VDS certified

Panel type

CF1100VDS

CF1200VDS

Standards

EN54 Pt2,1997, A1:2006,
EN54 Pt4,1997 A1:2002,A2:2006,
EN54 Pt13: 2005 

Number of loops

1

2

Addresses per loop

200

Panel sounder circuits

2

Auxiliary relay

One set of change over contacts, operated in the event of fire activation

Auxiliary fire routing
equipment output

Monitored 24V dc, 30 mA (max)

Auxiliary fire protection
equipment output

Monitored 24V dc, 30 mA (max)

Auxiliary fault routing
equipment output

Monitored 12V dc, 30 mA (max)

Output ports

RS485 and RS232 (for connection of repeaters etc)

Mains input voltage

230V ac +10% / -15%

System operating voltage

24V dc

Batteries

2 x 12V 7Ah

Standby duration

24 hours (subject to loop load)

Cable entries

11 top entry cable knockouts (20mm) plus rear entry cable aperture

Environmental rating

IP30, -5ºC to +40ºC, 75% RH (non condensing)

Size WxHxD (mm)

375x357x50

Weight

8kg

 

CF1100VDS

1-Loop panel

CF1100VDSNC

1-Loop panel c/w network card

CF1200VDS

2-Loop panel

CF1200VDSNC

2-Loop panel c/w network card

 

 

CF1000 Top Frequently Asked Questions

Why is my alarm going off?

The alarm will be going off because your fire panel has detected an issue. The panel will indicate what the problem is via the following lights:

  • RED “FIRE” – the system has detected a fire and the alarms should be sounding. The panel will also indicate which zone the fire has been detected in. The “evacuate” procedure must commence next and the source of the fire should be investigated.
  • ORANGE “GENERAL FAULT” – the fire panel has detected a general fault. The touch screen interface will display further information on the fault. 
  • ORANGE “GENERAL DISABLE” – the system has detected a disablement within the system. In this case it would be best to contact our technical team for further advice.
  • ORANGE “POWER FAULT” – the system has detected a fault with the mains power or batteries. Contact our service team to organise a visit from one of our engineers.
  • ORANGE “SYSTEM FAULT” – the panel has detected a fault within the system, please contact our technical team for further advice. 

How do I SILENCE my alarm?

  1. Select "SUPERVISOR MODE" on the top left hand corner of the touch screen.
  2. "ENTER 2214" (Access Code) and PRESS OK.
  3. Select "SILENCE ALARMS" from the top row.
  4. Select "YES". All sounders will now be silenced and the cause of the alarm must be investigated.

How to ENABLE my fire system?

  1. Select the "SUPERVISOR MODE" on the top left hand corner of the touch screen.
  2. "ENTER 2214" (Access Code) and "PRESS OK"
  3. Select “ENABLE/DISABLE” from the main menu
  4. Select the relevant option to enable your Network/ Zone/ I/O/Address or All
  5. Follow the on-screen instructions.

How to I DISABLE my fire system?

  1. Select "SUPERVISOR MODE" on the top left hand corner of the touch screen.
  2. "ENTER 2214" (Access Code) and "PRESS OK"
  3. Select “ENABLE/DISABLE” from the main menu
  4. Select the relevant option to disable your Network/ Zone/ I/O/Address or All
  5. Follow the on-screen instructions.

How do I MUTE my buzzer?

  1. Select "SUPERVISOR MODE" on the top left hand corner of the touch screen.
  2. "ENTER 2214" (Access Code) and "PRESS OK"
  3. Select the “MUTE BUZZER” option from the top of the main menu.
  4. Select “YES”. All sounders and relays will now be muted.

How do I run a WEEKLY TEST?

  1. Select "SUPERVISOR MODE" on the top left hand corner of the touch screen.
  2. "ENTER 2214" (Access Code) and "PRESS OK"
  3. Select “WEEKLY TEST” from the main page.
  4. Following the EN54 Message select “YES".
  5. Follow the normal proceedings for a weekly test i.e. enter your key into a call point. The panel will reset itself once the test is complete. 

Need more help?

For further help and support please contact our Technical Support team:

Technical Support
techsupport@cooperfire.com
Tel: 01302 303350
Fax: 01302 303332

Sales

Tel

01302 303999

Fax     

01302 303333

Email    

Sales@CooperFire.com


Export Sales

Tel

+44 (0) 1302 303344
Fax     

+44 (0) 1302 303345

Email    

Export@CooperFire.com