Conventional Detectors
Conventional Detectors
A comprehensive range of conventional detectors are available to operate with the Cooper conventional panel range.
Download Technical Documentation
Technical Documents
A comprehensive range of conventional detectors are available to operate with the Cooper conventional panel range.
Benefits and Features
- LPCB 3rd party approved / CPD approved
- Low profile design
- 360° viewable LED design
- Removable detector chamber for cleaning
- Common mounting base
- New enhanced detectors feature Dual LEDs,
- Drift compensation and Chamber monitoring (Optical & Photo-Thermal)
Model (UNB) |
CPD321 |
CPT341 |
CFR330 |
CMT360 |
CHT390 |
---|---|---|---|---|---|
Description |
Optical Sensor |
Photo-Themal Sensor |
Heat Sensor (Fast) |
Heat Sensor (Med) |
Heat Sensor (High) |
CPD approved product |
0832CPD0633 |
0832CPD0629 |
0832CPD0233 |
0832CPD0236 |
0832CPD0237 |
Standards |
EN54 pt7:2000 |
EN54 pt7:2000 |
EN54 pt5:2000 + A1:2002 |
||
+ A1:2002 |
+ A1:2002 |
|
|
|
|
|
EN54 pt5:2000 |
|
|
|
|
|
+ A1:2002 |
|
|
|
|
Area coverage |
100m² (subject to local standard) |
50m² (subject to local standard) |
|||
System wiring |
2 core |
||||
Indication |
360° visibility light pipe |
||||
Mounting |
Surface mount CDBB300, FXN520 base |
||||
Compatibility |
Conventional fire panels |
||||
Detetion Mode |
Light scatter principle |
Light scatter principle |
Heat sensitive element |
||
|
heat sensitive element |
|
|
|
|
Operating voltage |
15 to 30V dc |
||||
Max stand by current |
30μA |
||||
Max Start up current |
340μA |
|
|||
Max alarm current |
25mA |
||||
Heat class |
|
A2S |
A2R |
BS |
CS |
Alarm temperature |
|
60°C |
|
77°C |
92°C |
Environmental |
|
|
|
|
|
Application |
Indoor use IP 40 |
||||
Temperature |
-20°C to 60°C |
-20°C to 45°C |
-20°C to 60°C |
-20°C to 60°C |
-20°C to 75°C |
Humidity |
0 to 95% non condensing |
||||
EMC |
CE marked |
||||
Construction |
|
|
|
|
|
Material |
PC/ABS |
||||
Colour |
White |
||||
Dimensions |
|
|
|
|
|
Excluding Base (Dia x H) |
|
100mm x 43mm |
|||
Including Base (Dia x H) |
100mm x 45mm |
101mm x 55mm |
CPD321 | Optical Sensor |
CPT341 | Photo-Thermal Sensor |
CFR330 | Heat Sensor (Fast) |
CMT360 | Heat Sensor (Med) |
CHT390 | Heat Sensor (High) |
Unfortunately no online technical support is available for this product.
Please contact our Technical support team:
- Cooper Products
- Product Search
- Conventional
- Cooper's Control Panels
- Extinguishing Panels
- Cooper's Accessories
- Conventional Sounder
- Conventional Bells
- Conventional Callpoints
- Conventional Detectors
- Beam Detection
- Conventional Flush Sounder
- Conventional Sounder Beacon
- Conventional Base Mountable Sounder
- Conventional Sounder - Currently Discontinued
- Conventional Surface Sounders
- Conventional Sounders
- Duct Probe
- Bi-Wire Detector
- Conventional Ancillaries
- UL Listed Range
- Public Address & Voice Alarm
- Wireless - Currently Discontinued
- Intelligent Addressable
- VoCALL EVCS
- Speaker Range
- Menvier Products
- JSB Products
- Eaton Products
Eaton fire and voice alarm systems catalogue