Sorry, you need to enable JavaScript to visit this website.

Addressable Sensors

Addressable Sensors Sensors Range

Photoelectric smoke sensor (opto) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Download Technical Documentation

 

Photoelectric smoke sensor (opto) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Opto-heat sensor will respond better to fast clean burning fires yet maintain the advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also give an alarm at temperatures above 135°F.

Rate of rise with fixed heat sensor settings will detect a rapid increase in temperature or temperatures above 135°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.

Fixed heat sensors settings will detect temperatures above 135°F or 194°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. For photoelectric and opto-heat operation the sensor automatically compensates for gradual increase in the scatter signal due to contamination e.g. dust build up.

Features

  • Built-in short circuit isolators
  • Stylish low profile design
  • 360º viewable LED design
  • Removable detector chamber
  • Drift compensation

Benefits

  • Plug and play - no hard addressing required
  • ‘Clean me’ feature means sensor can be cleaned on site using Eaton's manual cleaning procedure
  • The programmable heat sensor reduces the number of parts required in the system

Code

ULCAP320

ULCAPT340

ULCAH330

Description

Addressable Sensor, Optical

Addressable Sensor, Opto-Heat

Addressable Sensor, Multi-Mode Heat

Standards

UL268

UL268

UL521

Supply Ratings

Working Voltage

18 V dc to 30 V dc

18 V dc to 30 V dc

18 V dc to 30 V dc

Voltage Waveform

Filtered dc +/- 1 V (max), ripple @120Hz

Filtered dc +/- 1 V (max), ripple @120Hz

Filtered dc +/- 1 V (max), ripple @120Hz

Standby Current

220 μA (average)

220 μA (average)

220 μA (average)

Alarm Current

5 mA (max)

5 mA (max)

5 mA (max)

Timings

Start-up Time

2 seconds

2 seconds

2 seconds

Reset Time

2 seconds (max)

2 seconds (max)

2 seconds (max)

Sensitivity

Sensitivity

2.55+/- 0.33%/ft

2.55+/- 0.33%/ft

N/A

Sensitivity Checker

Use No-Climb, TRUTEST, UL Listing 77TL

Use No-Climb, TRUTEST, UL Listing 77TL

Use No-Climb, TRUTEST, UL Listing 77TL

Heat Class

Heat Element Rating

N/A

135ºF

135ºF ROR + Fixed, + Fixed 135ºF Fixed, 194ºF Fixed

Heat Detector Spacing

N/A

50ft (heat alone operation)

50ft

Mounting Position

Ceiling in open areas

Ceiling in open areas

Ceiling in open areas

Environmental

Operating Temperature

32ºF to 100ºF

32ºF to 100ºF

32ºF to 100ºF / 32ºF to 150ºF (194ºF setting)

Compatibility

Compatibility Indentifier

W002

W002

W002

Compatible Bases

WBA or UCAB300

WBA or UCAB300

WBA or UCAB300

Suitable for use with

Cooper UL fire systems

Cooper UL fire systems

Cooper UL fire systems

 

Code Description
ULCAP320 Addressable Sensor, Optical
ULCAPT340 Addressable Sensor, Opto Heat
ULCAH330 Addressable Sensor, Multi-Mode Heat,
(Programmable as Rate of Rise 135°F or 194°F)

 

Unfortunately no online technical support is available for this product.
Please contact our Technical support team:

Technical Support
techsupport@cooperfire.com
Tel: 01302 303350
Fax: 01302 303332